Initial Assays Confirm High Grade Primary REE and Niobium
Released
Released
Announcement PDF
ASX / MEDIA ANNOUNCEMENT
10 November 2021
Initial Assays Confirm High Grade Primary Rare Earth
and Niobium Mineralisation at Cummins Range
Thick, high-grade mineralisation in first diamond hole confirms outstanding upside in the primary zone
HIGHLIGHTS
• Significant primary mineralisation confirmed in diamond drill-hole CDX007, which returned an
outstanding intercept of:
•
34.6m at 1.3% TREO and 0.4% Nb2O5, including 3.6m at 2.5% TREO and 0.7% Nb2O5
within an overall zone of 61.4m at 1% TREO and 0.3% Nb2O5
• Reverse Circulation (RC) drill-hole CRX0066 intersected two wide breccia zones with significant
rare earths mineralisation, returning an intercept of:
•
40m at 1.8% TREO and 0.3% Nb2O5, including 13m at 3.1% TREO and 0.4% Nb2O5
• Below this zone was a further wide zone comprising:
•
31m at 1.4% TREO and 0.4% Nb2O5, including 3m at 3.3% TREO and 0.3% Nb2O5
• Attractive economic drivers in the primary zone
•
Neodymium-Praseodymium (NdPr) ratio in the primary zone is the same as in the
weathered and is up to 24% NdPr comparable with the Mt Weld deposit also in Western
Australia
•
Niobium grade of 0.4% Nb2O5 is twice the current resource grade and comparable with
other known deposits such as the Niobec Mine in Quebec, Canada
• Deeper hole, CDX0016, has intersected multiple stacked lenses, all with massive to
disseminated rare earths as monazite
• Further assays expected to come over the next two months
RareX Limited (ASX: REE; RareX or the Company) is pleased to report initial assays from diamond
drilling targeting the high-grade primary mineralisation at its 100%-owned Cummins Range Rare
Earths Project in the Kimberley Region of Western Australia with a Mineral Resource of 18.8Mt
at 1.15% TREO + 0.14% Nb2O5 (Indicated Resource of 11.1Mt at 1.34% TREO + 0.17% Nb2O5;
Inferred Resource of 7.7Mt at 0.88% TREO+ 0.11% Nb2O5 (0.5% TREO cut-off)) including highgrade tonnes to 6.5Mt at 1.98% TREO (inc. 0.38% NdPr) + 0.21% Nb2O5.
These highly encouraging initial assays, coupled with further visual results from recent drilling,
provide further strong evidence that there is a substantial high-grade primary mineralized zone
at Cummins Range offering significant potential to expand the current Mineral Resource.
All of the Reverse Circulation (RC) drill assays have also now been received, together with a
portion of assays from diamond hole CDX0007. The remainder of the assays are expected to be
received over the next two months.
RareX Limited
Unit 6, 94 Rokeby Road, Subiaco WA 6008 Ph: 08 6383 6593 ACN: 105 578 756
1
Hole CDX0007, shown in Figure 1, is the first assayed diamond drill-hole at Cummins Range in 40
years and was drilled into an area where a displacement fault had been interpreted.
This interpretation has now been supported by the hole intersecting a 77m wide breccia zone
that has assayed 61.4m at 1% TREO and 0.3% Nb2O5.
The lower 34.6m of this breccia is in fresh rock with common disseminations of monazite grading
at 34.6m at 1.3% TREO and 0.4% Nb2O5, including 3.6m at 2.5% TREO and 0.7% Nb2O5.
RareX’s view is that this provides clear evidence that the primary zone can host significant highgrade mineralisation, opening up substantial growth opportunities for the Cummins Range
Project at depth below the weathered zone.
RC drill hole CRX0066 was completed 90m to the north-east of CDX0007 and intersected two
wide breccia zones with significant rare earths mineralisation, the first of which comprises 40m
at 1.8% TREO and 0.3% Nb2O5, including 13m at 3.1% TREO and 0.4% Nb2O5.
Below this zone was another zone of 31m at 1.4% TREO and 0.3% Nb2O5, including 3m at 3.3%
TREO and 0.3% Nb2O5. These intersections are considered to be true width. The geological
understanding of this area is a high priority for RareX and a further three diamond drill holes have
been drilled with assays pending.
Figure 1: CDX0007 Cross Section with Assay Results and Geology
RareX Limited
Unit 6, 94 Rokeby Road, Subiaco WA 6008 Ph: 08 6383 6593 ACN: 105 578 756
2
Figure 2: CRX0066 Cross Section with Assay Results and Geology
Fresh rock intersections into the targeted Main Fault have delivered several well-mineralised
zones that have been confirmed with a portable XRF. A series of mineralised stacked lenses in
the hanging wall and footwall have also been drilled on multiple sections.
These zones vary in size, geology and grade.
Figure 3: Cummins Range Vertical Long Projection of the Main Fault
RareX Limited
Unit 6, 94 Rokeby Road, Subiaco WA 6008 Ph: 08 6383 6593 ACN: 105 578 756
3
Figure 4: Cummins Range Drill Plan Showing REE Mineralisation and 2021 Drill Holes
Figure 5 shows a cross-section with previously announced hole CRX0063 (41m at 2.4% TREO and
0.5% Nb2O5, including 10m at 4.1% TREO, as reported in the ASX announcement of 9 September
2021) and three diamond drill holes, CDX0011, CDX0012 and CDX0016.
The deeper hole, CDX0016, intersected multiple zones – all with disseminated to massive
monazite. The deepest zone is 12m wide and 275m down-hole and is shown in photo 1. The zone
is composed of patchy massive monazite on an ultramafic carbonatite contact.
Assays are pending.
RareX Limited
Unit 6, 94 Rokeby Road, Subiaco WA 6008 Ph: 08 6383 6593 ACN: 105 578 756
4
Figure 5: Cummins Range Cross Section with Stacked Lenses
Photo 1: Cummins Range deepest intercept to date with patchy to massive monazite – outlines of the massive monazite in blue
(note: monazite typically runs 60-70% TREO)
RareX Limited
Unit 6, 94 Rokeby Road, Subiaco WA 6008 Ph: 08 6383 6593 ACN: 105 578 756
5
The 2021 drill program has been suspended due to the early arrival of the wet season in the
Kimberley. A total of 5,272m of drilling was completed comprising 3,001m of diamond core
drilling and 2,271m of RC drilling.
Commenting on the results, RareX’s Managing Director, Jeremy Robinson, said:
“We are very pleased with the initial results of what has been the first diamond drill
program to be undertaken at Cummins Range in over 40 years.
“The presence of disseminated to massive monazite in fresh rock over multiple lenses to
depths of nearly 300m is very encouraging and highlights the huge potential of the underexplored Cummins Range Carbonatite.
“While the early onset of the wet season has forced us to suspend drilling for the time
being, we were able to complete over 5,000m including over 3,000m of diamond core. We
have a large number of assays that will be received over the wet season, generating strong
news-flow over the next 2-3 months that will help to scope out the potential of the
Cummins Range Project as a major new rare earths development opportunity.”
This announcement has been authorised for release by the Board of RareX Limited.
For further information, please contact:
RareX Limited
Jeremy Robinson
Managing Director
Ph: 08 6383 6593
Media Enquiries
Nicholas Read
Read Corporate
Ph: 08 9388 1474
Competent Person’s Statements
Information in this release that relates to Exploration Results is based on and fairly represents information
and supporting documentation reviewed or compiled by Mr Guy Moulang, an experienced geologist
engaged by RareX Limited. Mr Moulang is a Member of the Australian Institute of Geoscientist and has
sufficient experience which is relevant to the styles of mineralisation and types of deposits under
consideration and to the activities being undertaken to qualify as a Competent Person as defined in the
2012 Edition of the “Australasian Code for Reporting of Exploration Results, Mineral Resources and Ore
Reserves”. Mr Moulang consents to the inclusion in this release of the matters based on his information
in the form and context in which it appears.
The mineral resource estimate in this announcement were reported by the Company in accordance with
listing rule 5.8 on 19 July 2021. The Company confirms it is not aware of any new information or data that
materially affects the information included in the previous announcement and that all material
assumptions and technical parameters underpinning the estimates in the previous announcement
continue to apply and have not materially changed.
RareX Limited
Unit 6, 94 Rokeby Road, Subiaco WA 6008 Ph: 08 6383 6593 ACN: 105 578 756
6
Appendix 1: Significant Intercept Table
Hole ID
From
To
Interval
TREO %
CRX0062
Incl.
CRX0062
CRX0062
CRX0062
CRX0062
CRX0065
CRX0065
CRX0065
CRX0065
CRX0065
CRX0065
CRX0065
CRX0066
Incl.
CRX0066
Incl.
CRX0066
CRX0067
CRX0067
CRX0067
CRX0067
CRX0067
CRX0069
CRX0069
CRX0069
CRX0069
CRX0070
CRX0070
CRX0070
CWB3
CWB3
CWB3
Incl.
CDX0007
Incl.
Incl.
3
18
42
54
75
87
15
20
31
53
90
94
97
29
38
91
94
129
27
44
48
53
99
54
63
71
107
45
104
138
0
5
15
15
81.6
83.9
120.6
34
29
47
55
78
90
16
25
34
55
92
95
98
69
51
122
97
132
29
46
49
83
101
59
65
73
108
58
113
142
1
6
48
18
143
87
124.2
31
11
5
1
3
3
1
5
3
2
2
1
1
40
13
31
3
3
2
2
1
30
2
5
2
2
1
13
9
4
1
1
33
3
61.4
3.1
3.6
5.52
10.47
0.74
0.63
1.24
1.89
1.34
1.26
0.92
0.82
2.42
0.64
0.59
1.81
3.07
1.4
3.34
0.52
0.76
0.63
0.62
0.81
0.67
0.67
0.58
0.57
0.84
0.59
0.56
0.59
0.66
0.58
2.36
9.09
1.01
2.31
2.53
% NdPr of
TREO
21%
20%
20%
21%
20%
17%
18%
21%
23%
18%
19%
21%
18%
20%
20%
20%
18%
20%
18%
22%
21%
23%
22%
23%
26%
25%
19%
24%
25%
23%
18%
18%
20%
20%
22%
18%
24%
NdPr %
Nb2O5 %
P2O5 %
1.16
2.09
0.15
0.13
0.25
0.32
0.24
0.26
0.21
0.15
0.46
0.13
0.11
0.36
0.61
0.28
0.6
0.1
0.14
0.14
0.13
0.19
0.15
0.15
0.15
0.14
0.16
0.14
0.14
0.14
0.12
0.1
0.47
1.82
0.22
0.42
0.61
0.50
0.73
0.10
0.10
0.09
0.06
0.04
0.32
0.11
0.23
0.04
0.07
0.04
0.28
0.39
0.39
0.31
0.14
0.04
0.09
0.05
0.09
0.07
0.20
0.05
0.06
0.03
0.07
0.05
0.02
0.07
0.06
0.37
0.75
0.25
0.08
0.66
8.5
11.4
6.9
10.8
5.7
5.0
2.9
12.9
11.4
6.1
2.7
5.1
1.7
17.5
10.7
18.4
14.4
5.5
2.9
29.9
5.6
19.6
8.2
20.5
18.1
15.4
4.9
11.8
12.9
4.2
1.1
0.7
14.5
9.1
14.8
13.5
19.7
TREO = Lanthanide Oxides + Ytrium Oxide + Scandium Oxide
RareX Limited
Unit 6, 94 Rokeby Road, Subiaco WA 6008 Ph: 08 6383 6593 ACN: 105 578 756
7
Appendix 2: Collar Table
Hole ID
North
MGA
7866481
7866751
7866604
7866709
7866720
7866736
7866370
7866540
7866712
7866762
7866679
7866648
7866568
7866640
7866644
7866694
7866505
7866598
7866531
7866498
RLUTM
CRX0059
CRX0060
CRX0061
CRX0062
CRX0063
CRX0064
CRX0065
CRX0066
CRX0067
CRX0068
CRX0069
CRX0070
CWB3
CDX0001
CDX0002
CDX0003
CDX0004
CDX0005
CDX0006
CDX0007
East
MGA
307462
307139
306998
307223
307106
307399
307530
307348
307435
307430
307454
307477
307415
307286
307078
307192
307341
307140
307191
307267
Azimuth
Dip
Type
Assays
391
392
392
392
392
391
390
391
391
391
391
391
391
391
393
392
391
393
393
393
End
Depth
96
120
120
108
144
120
120
132
120
96
120
144
48
11.7
135.8
96.5
155.1
210.4
215.8
198.8
50
50
50
180
50
50
50
90
50
50
50
50
90
50
50
50
50
50
50
50
60
60
60
60
60
60
60
90
60
60
60
60
90
60
60
60
60
60
60
60
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
Diamond
Diamond
Diamond
Diamond
Diamond
Diamond
Diamond
393
393
393
393
393
393
393
393
393
393
391
392
218.4
213.4
231.3
227.3
210.9
204.8
227.4
204.6
298.1
215.3
288.7
219.6
50
50
50
50
50
50
50
50
50
50
50
50
60
60
60
60
60
60
60
60
60
60
60
60
Diamond
Diamond
Diamond
Diamond
Diamond
Diamond
Diamond
Diamond
Diamond
Diamond
Diamond
Diamond
Received
Received
Received
Received
Received
Received
Received
Received
Received
Received
Received
Received
Received
Awaiting
Awaiting
Awaiting
Awaiting
Awaiting
Awaiting
Partly
Received
Awaiting
Awaiting
Awaiting
Awaiting
Awaiting
Awaiting
Awaiting
Awaiting
Awaiting
Awaiting
Awaiting
Awaiting
CDX0008
CDX0009
CDX0010
CDX0011
CDX0012
CDX0013
CDX0014
CDX0015
CDX0016
CDX0017
CDX0018
CDX0019
307237
307325
307158
307072
307037
307047
307015
307372
307007
307079
307127
307305
7866469
7866442
7866507
7866691
7866666
7866717
7866692
7866769
7866637
7866651
7866482
7866530
RareX Limited
Unit 6, 94 Rokeby Road, Subiaco WA 6008 Ph: 08 6383 6593 ACN: 105 578 756
8
Appendix 3: JORC Tables
JORC Code, 2012 Edition – Table 1
Cummins Range Section 1 Sampling Techniques and Data
Criteria
JORC Code Explanation
Sampling
techniques
Nature and quality of sampling (eg cut channels, random chips, or specific specialised industry standard
measurement tools appropriate to the minerals under investigation, such as down hole gamma sondes, or
handheld XRF instruments, etc). These examples should not be taken as limiting the broad meaning of sampling.
Include reference to measures taken to ensure sample representivity and the appropriate calibration of any
measurement tools or systems used.
Aspects of the determination of mineralisation that are Material to the Public Report. In cases where ‘industry
standard’ work has been done this would be relatively simple (eg ‘reverse circulation drilling was used to obtain 1
m samples from which 3 kg was pulverised to produce a 30 g charge for fire assay’). In other cases more
explanation may be required, such as where there is coarse gold that has inherent sampling problems. Unusual
commodities or
mineralisation types (eg submarine nodules) may warrant disclosure of detailed information.
•
•
•
•
•
•
•
•
Drilling
Techniques
Drill Sample
Recovery
Logging
Drill type (eg core, reverse circulation, open- hole hammer, rotary air blast, auger, Bangka, sonic, etc) and details
(eg core diameter, triple or standard tube, depth of diamond tails, face-sampling bit or other type, whether core is
oriented and if so, by what method, etc).
Method of recording and assessing core and chip sample recoveries and results assessed.
Measures taken to maximise sample recovery and ensure representative nature of the samples.
Whether a relationship exists between sample recovery and grade and whether sample bias may have occurred
due to preferential loss/gain of fine/coarse material.
Whether core and chip samples have been geologically and geotechnically logged to a level of detail to support
appropriate Mineral Resource estimation, mining studies and metallurgical studies.
RareX Limited
Suite 23, 513 Hay Street, Subiaco WA 6008 Ph: 08 6143 6720 ACN: 105 578 756
9
•
•
•
•
The Cummins Range Rare Earth deposit is being drilled tested with
RC drilling and diamond drilling.
The RC drill rig used a 5 ½ inch diameter hammer. Each 1m bulk
sample was collected in a plastic bag.
Diamond drill sizes used are PQ, HQ and NQ2
Each metre was analysed with a portable XRF, and recovery and
geology logs were completed.
Sample interval selection was based on geological controls and
mineralisation
Each 1m RC bulk sample was split with a riffle splitter to the
appropriate size. Samples varied in length from 1m to 4m.
Each core sample was cut in half with a brick saw. The half core
sample was sent to the laboratory with intervals ranging from 0.3m
to 1.3m.
Samples were assayed for 42 elements using either a peroxide fusion
with a ICP-OES and ICP-MS finish, or a four acid digest with a ICP-OES
and ICP-MS finish
Prefix CRX drill holes are reverse circulation (RC) drilling
Prefix CDX are diamond drilling. 11 of the diamond drill holes were
started with an RC precollar ranging from 40-90m depth. Holes were
then continued with HQ3 or NQ2 diamond core
5 diamond drill holes were drilled core from surface.
Recoveries for all drill holes were recorded for each metre. CRX0062
94%, CRX0065 99%, CRX0066 90%, CRX0067 98%, CRX0069 96%,
CRX0070 95%, CDX0007 79.4-144m 90%
Whether logging is qualitative or quantitative in nature. Core (or costean, channel, etc) photography.
The total length and percentage of the relevant intersections logged.
Sub-sampling
techniques
and sample
preparation
If core, whether cut or sawn and whether quarter, half or all core taken.
If non-core, whether riffled, tube sampled, rotary split, etc and whether sampled wet or dry.
For all sample types, the nature, quality and appropriateness of the sample preparation technique.
Quality control procedures adopted for all sub-sampling stages to maximise representivity of samples.
Measures taken to ensure that the sampling is representative of the in situ material collected, including for
instance results for field duplicate/second-half sampling.
Whether sample sizes are appropriate to the grain size of the material being sampled.
Quality of
assay data
and
laboratory
tests
The nature, quality and appropriateness of the assaying and laboratory procedures used and whether the
technique is considered partial or total
For geophysical tools, spectrometers, handheld XRF instruments, etc, the parameters used in determining the
analysis including instrument make and model, reading times, calibrations factors applied and their derivation, etc.
Nature of quality control procedures adopted (eg standards, blanks, duplicates, external laboratory checks) and
whether acceptable levels of accuracy (ie lack of bias) and precision have been established.
Verification
of sampling
and assaying
The verification of significant intersections by either independent or alternative company personnel.
The use of twinned holes.
The verification of significant intersections by either independent or alternative company personnel.
Discuss any adjustment to assay data.
Location of
data points
Accuracy and quality of surveys used to locate drill holes (collar and down-hole surveys), trenches, mine workings
and other locations used in Mineral Resource estimation.
Specification of the grid system used.
RareX Limited
Suite 23, 513 Hay Street, Subiaco WA 6008 Ph: 08 6143 6720 ACN: 105 578 756
10
All metres drilled had a geology log completed. Geology logs were
aided using geochemical analysis from a portable XRF.
•
The detail of logging is appropriated for Mineral Resource
estimation.
•
Splits from the drill rig were not used. The entire 1m bulk sample
was split with a riffle splitter to the appropriate size. Samples varied
in length from 1m to 4m.
•
This RC sampling technique is better than industry standards and is
appropriate for this style of mineralisation and for resource
estimation.
•
Diamond core was cut in half with a brick saw and half the core was
sent to the laboratory. This is an appropriate method for this style of
mineralisation and for resource estimation.
The reported assays were analysed by Nagrom. The following techniques were
used:
•
28 elements were assayed for using peroxide fusion with a ICP-OES
and ICP-MS finish
•
14 elements were assayed for using four acid digest with a ICP-OES
and ICP-MS finish
•
In addition to internal checks by Nagrom, RareX incorporates a
QA/QC sample protocol utilizing prepared standards, blanks and
duplicates for 8% of all assayed samples.
•
Significant intercepts were calculated by RareX geological staff.
•
The intercepts have not been verified by independent persons
•
There are numerous drill holes with in the Cummins Range resource
of comparable tenure
•
All assay results are reported to RareX in parts per million (ppm).
RareX geological staff then convert the parts per million to ppm
oxides using the below element to stoichiometric oxide conversion
factors. La2O3 1.1728, CeO2 1.2284, Pr6O11 1.2082, Nd2O3 1.1664,
Sm2O3 1.1596, Eu2O3 1.1579, Gd2O3 1.1526, Dy2O3 1.1477, Ho2O3
1.1455, Er2O3 1.1435, Tm2O3 1.1421, Yb2O3 1.1387, Lu2O3 1.1371,
Sc2O3 1.5338, Y2O3 1.2699, Nb2O5 1.4305, P2O5 2.2916
•
Drill hole collars were located by handheld GPS
•
All coordinates are in MGA Zone 52H 1994
•
Quality and adequacy of topographic control.
•
•
Data spacing
and
distribution
Orientation
of data in
relation to
geological
structure
Sample
security
Data spacing for reporting of Exploration Results.
Whether the data spacing and distribution is sufficient to establish the degree of geological and grade continuity
appropriate for the Mineral Resource and Ore Reserve estimation procedure(s) and classifications applied.
Whether sample compositing has been applied.
•
Whether the orientation of sampling achieves unbiased sampling of possible structures and the extent to which this
is known, considering the deposit type.
If the relationship between the drilling orientation and the orientation of key mineralised structures is considered
to have introduced a sampling bias, this should be assessed and reported if material.
•
The measures taken to ensure sample security
•
RareX Limited
Suite 23, 513 Hay Street, Subiaco WA 6008 Ph: 08 6143 6720 ACN: 105 578 756
11
•
Topographic control is maintained by the use of previously surveyed
drill holes. The Cummins Range deposit is located in flat terrain.
Down hole surveys were taken every 30m, using a digital Reflex
multi shot camera.
The purposed of the drill program is to test for primary
mineralisation below the regolith. Drill spacing 40m on 80m drill
lines is appropriate to establish geological and grade continuity.
2m to 4m RC composites were completed in areas where higher
grades were not expected
The angled drill holes were directed as best possible across the
known geology.
Drill samples are delivered to Halls Creek by RareX staff. Then the
samples are transported from Halls Creek to Perth via a reputable
transport company.
Cummins Range Section 2 Reporting of Exploration Results
Criteria
Mineral
tenement and
land tenure
status
Exploration
done by other
parties
JORC Code Explanation
Type, reference name/number, location and ownership including agreements or material
issues with third parties such as joint ventures, partnerships, overriding royalties, native title
interests, historical sites, wilderness or national park and environmental settings.
The security of the tenure held at the time of reporting along with any known impediments
to obtaining a licence to operate in the area.
Acknowledgment and appraisal of exploration by other parties.
•
•
Geology
Deposit type, geological setting and style of mineralisation.
•
Drill hole
information
A summary of all information material to the understanding of the exploration results
including a tabulation of the following information for all Material drill holes:
easting and northing of the drill hole collar
elevation or RL (Reduced Level – elevation above sea level in metres) of the drill hole
collar
dip and azimuth of the hole
down hole length and interception depth
hole length.
If the exclusion of this information is justified on the basis that the information is not
Material and this exclusion does not detract from the understanding of the report, the
Competent Person should clearly explain why this is the case.
•
RareX Limited
Suite 23, 513 Hay Street, Subiaco WA 6008 Ph: 08 6143 6720 ACN: 105 578 756
12
The Cummins Range REO deposit is located on tenement E80/5092 and is 100% owned
by Cummins Range Pty Ltd which is a wholly owned subsidiary of RareX Ltd. Cummins
Range Pty Ltd has purchased the tenement from Element 25 with a potential capped
royalty payment of $1m should a positive PFS be completed within 36 months of
purchase finalisation.
CRA Exploration defined REO mineralisation at Cummins Range in 1978 using
predominantly aircore drilling. Navigator Resources progressed this discovery with
additional drilling after purchasing the tenement in 2006. Navigator announced a
resource estimate in 2008. Kimberly Rare Earths drilled additional holes and upgraded
the resource estimate in 2012.
The Cummins Range REO deposit occurs within the Cummins Range carbonatite
complex which is a 2.0 km diameter near-vertical diatreme pipe that has been deeply
weathered but essentially outcropping with only thin aeolian sand cover in places. The
diatreme pipe consists of various mafic to ultramafic rocks with later carbonatite
intrusions. The primary ultramafic and carbonatite rocks host low to high grade rare
earth elements with back ground levels of 1000-2000ppm TREO and high grade zones
up to 8% TREO. The current resource sits primarily within the oxidised/weathered zone
which reaches to 120m below the surface. Metallurgical studies by previous explorers
and by RareX show the rare earth elements are hosted by Monazite which is a common
and favourable host for rare earth elements.
All drill hole locations are shown in Figure 4 and collar details are in Appendix 2
Data
aggregation
methods
Relationship
between
mineralisation
widths and
intercept
lengths
Diagrams
Balanced
reporting
Other
substantive
exploration data
Further work
In reporting Exploration Results, weighting averaging techniques, maximum and/or
minimum grade truncations (eg cutting of high grades) and cut-off grades are usually
Material and should be stated.
Where aggregate intercepts incorporate short lengths of high grade results and longer
lengths of low grade results, the procedure used for such aggregation should be stated and
some typical examples of such aggregations should be shown in detail.
The assumptions used for any reporting of metal equivalent values should be clearly stated.
These relationships are particularly important in the reporting of Exploration Results
If the geometry of the mineralisation with respect to the drill hole angle is known, its nature
should be reported.
If it is not known and only the down hole lengths are reported, there should be a clear
statement to this effect (eg ‘down hole length, true width not known’).
•
•
•
•
Significant intercepts were calculated using weighted averaging
A lower cut off of 0.5% TREO was used with a maximum of 5m dilution. This cut off
grade and dilution is thought to be appropriate due to likely open cut mining methods
that would be used on the outcropping ore body.
No metal equivalent values have been used
All the RC drill holes except CRX0062 and CWB3 have been drilled perpendicular to the
target horizon and are true width intercepts. The below drill holes are not true widths
are down hole intercepts. Estimated true widths are shown below.
CRX0062 – true width is 20% of the intercept, mining studies hole
CWB3 – true width is 40% of the intercept, water monitoring bore
Appropriate maps and sections (with scales) and tabulations of intercepts should be included
for any significant discovery being reported These should include, but not be limited to a plan
view of drill hole collar locations and appropriate sectional views.
Where comprehensive reporting of all Exploration Results is not practicable, representative
reporting of both low and high grades and/or widths should be practiced to avoid misleading
reporting of Exploration Results.
Other exploration data, if meaningful and material, should be reported including (but not
limited to): geological observations; geophysical survey results; geochemical survey results;
bulk samples – size and method of treatment; metallurgical test results; bulk density,
groundwater, geotechnical and rock characteristics; potential deleterious or contaminating
substances.
•
5 maps are shown within the announcement
•
Reporting is considered balanced
•
This announcement describes the initial geological interpretations of the first diamond
drill holes at Cummins Range since the early 1980s. RareX have recently completed a
JORC compliant resource upgrade of 18.8Mt at 1.15% TREO + 0.14% Nb2O3.
Metallurgical studies are currently being conducted. Mining study drill holes have been
drilled in recent weeks.
The nature and scale of planned further work (eg tests for lateral extensions or large scale
step out drilling.
Diagrams clearly highlighting the areas of possible extensions, including the main geological
interpretations and future drilling areas, provided this information is not commercially
sensitive.
•
•
•
Awaiting assays to completed geological interpretation
Metallurgical tests are being conducted
Scoping studies are being conducted
RareX Limited
Suite 23, 513 Hay Street, Subiaco WA 6008 Ph: 08 6143 6720 ACN: 105 578 756
13
Share your feedback
Discover